5 Replacement
72
S84-ex/S86-ex Service Manual
14
Connect the sensor cable to the new
bottom media sensor PCB . Then,
attach the new bottom media sensor
PCB to the sensor bracket using
two screws .
15
Attach the sensor bracket to the
center frame using two screws .
16
Attach the media sensor assembly to
the center frame using two screws .
Make sure that the media sensor assembly can
be locked properly.
After replacement
Adjust the media sensor.
Refer to Adjusting the Media Sensors in chapter 5 of S84-ex/S86-ex operator manual.
Adjust the position of the media sensor.
Refer to Adjusting the Position of the Media Sensor in chapter 3 of S84-ex/S86-ex operator
manual.
Perform test print to ensure proper function.
Refer to Section 4.3 Test Print Check for details.