hours
without
deterioration.
Should
replacement
be
indicated
by
loss
in
out-
put
or
low
plate
current
(usually
both),
it
is
recommended
that
a
complete
new
set
be
installed.
IMPORTANT
THE
(6JE6)
TUBES
USED
IN
THE
SB2-LA
ARE
FACTORY
BAL-
ANCED.
WHEN
REPLACING,
BALANCED
TUBES
MAY
BE
OB-
TAINED
THROUGH
YOUR
SBE
DEALER
OR
CHECK
STOCK
TUBES
FOR
BALANCED
MU.
It
will
be
found
that
standby
current
will
run
rather
high
for
the
first
hour
or
so
of
operation
and
this
will
gradually
fall
to
the
correct
level.
If
necessary,
the
bias
should
be
adjusted
as
required
until
the
new
tubes
age
a
Lit.
A
slight
blue
glow
within
the
tube
does
not
necessarily
indicate
a
defective
iube.
However,
if
plate
current
is
radically
high
or
low,
suspect
a
defective
tube.
This
is
usually
indicated
by
excessive
blue
glow,
color
on
the
plate
or
the
tube
envelope
abnormally
cool.
.
NOTE:
In
the
event
of
any
component
failure,
fuse
F2
should
always
be
checked
to
see
that
it
is
intact.
The
unit will
transmit
properly
if
the
fuse
is
open,
but
~
undue
stress
will
be
placed
on
the
power
supply
components
which
will
reduce
their
life.
F2
should
not
fail
except
under
a
prolonged
B
supply
short
circuit.