Do you have a question about the Scale House ATM Series and is the answer not in the manual?
Material | Steel |
---|---|
Application | Truck weighing |
Power Supply | 110V AC |
Environmental Protection | Weatherproof and corrosion-resistant |
Certifications | NTEP |
Describes a knob under the ATMI scale for sealing IP67 when washing or IP65 when weighing.
Instructions for adjusting adjustable feet to ensure platform stability and uniform resting of all corners on the ground.
Details powering the indicator via mains adapter or battery, including the turn-on/turn-off procedure and initial status messages.
Explains how to operate the scale using the battery, including charging indicators, low battery warnings, and charging duration.
Details the specific functions of each key on the front panel, including ON/OFF, ZERO, and TARE buttons.
Explains the meaning of the 'CHARGE' indicator light, relating it to battery charging status.
Explains the automatic zeroing function that occurs when the scale starts up, including behavior with and without approved instruments.
Describes how to manually set the zero point of the scale at any time, and the automatic rezeroing function.
Details the process of taring the scale, including how to tare containers, subtract weights, and remove tares.
Explains limitations on tare functions, particularly when the SEMI AUTOMATIC TARE is used and for approved instruments.
Instructs users on how to respond to overload messages and beeping sounds to prevent damage to the load cell.
Guides the user through the procedure for using the scale as a piece counter, including sample selection and average piece weight calculation.
Details the quantity check function using two thresholds for weight or pieces, and how to configure them.
Step-by-step instructions on setting the lower and upper weight thresholds for the quantity check function.
Explains the messages (HI, OK, LO) displayed based on the detected weight relative to the configured thresholds.
Describes how to convert between kilograms (kg) and grams (g) by pressing the TARE key length.
Explains the programmable automatic turn-off feature that saves energy when the scale is not in use.
Describes a function to test the scale by displaying weight with 10 times the minimum division in the calibration phase.
Provides a visual block diagram of the SET-UP environment, outlining the available parameter categories (F0 CAL to F11 rSt).
Detailed steps for calibrating the scale, including setting gravitational acceleration and sample weights.
Instructions for setting the scale's total divisions, with options for ATM and ATMI models.
Explains how to view the A/D converter points relative to the weight on the scale by pressing the TARE key.
Details how to set the display backlight functioning mode, with options for always off, always on, or automatic.
Allows setting the minutes of inactivity before the scale automatically switches off to save energy.
Procedure to set the scale's capacity after entering a password, with options for different weight limits.
Sets the divisions' number for zero tracking to compensate for thermal drift, affecting stability.
Allows adjustment of the ADC converter reading speed, affecting the number of readings per second.
Enables or disables limitations on the tare functions, referring to section 6.3.1 for details.
Selects the gravitational acceleration value for the instrument's use zone, allowing manual entry.
Provides a reset function, indicated as being for manufacturer use.