below
a
preset
level
the
"LO
BATT™
annunciator
light
will
blink
signalling
the
operator
that
the
battery
is
wearing
down.
This
is
a
preliminary
warming.
Immediate
action
is
not
required
as
there
are
séveral
weighings
left
in
the
battery
when
the
"LO
BATT”
warning
is
activated.
The
batteries
should
be
replaced
within
a
few
days
of
this
warning.
A
second
low
battery
condition
is
detected
when
the
voltage
fs
inadequate
to
accurately
operate
the
scale.
At
this
point
the
"LO
BATT”
annunciator
will
continue
to
blink,
and
the
scale
will
display
"bAttrý“
on
the
weight
display
accompanied
by
a
series
of
four
long
beeps.
This
is
done
to
eliminate
the
possibility
of
displaying
erroneous
weights
by
preventing
the
scale
from
being
used.
Ifthe
batteries
are
replaced
when
the
"LO
BATT"
signal
activates
this
additional
"low-low
battery”
signal
will
never
be
seen.
The
batteries
for
the
models
5002,
6002,
6502,
and
6702
are
located
under
an
access
door
on
the
rear
of
the
mast.
Two
"quarter-turn"
fasteners
hold
the
cover
in
place.
Use
a
dime
coin
or
screwdriver
to
rotate
the
fastener
a
quarter
of
a
turn.
Replace
all
six
(6)
of
the
cells
with
fresh
alkaline
heavy-duty
batteries.
Be
sure
to
observe
proper
polarity
of
the
cells
as
they
are
installed.
Replace
the
cover
and
fasten
securely
with
the
quarter-turn
fastener
using
a
dime
or
screwdriver.
Depending
on
the
readout
configuration
the
batteries
for
the
model
5662
may
be
accessed
by
removing
a
cover
or
the
top
of
the
readout
cabinet.
These
may
be
size
"D"
or
"C”
alkaline
cells.
The
date
of
battery
replacement
should
be
noted
on
the
battery
replacement
label
provided
on
the
underside
of
the
cover.
In
situations
where
the
scale
is
not
used
extensively
the
batteries
should
be
replaced
annually
just
as
a
precaution.
The
model 6162
built-in
scale
employs
a
rechargeable
nickel-cadmium
battery
to
power
the
internal
printer
and
provide
operation
during
power
outages.
This
battery
should
last
several
years
in
normal
operation
but
will
eventually
deteriorate
due
to
age.
The
replacement
battery
is
SCALE-TRONIX®
part
number
360007.
To
replace
the
6102's
battery
unplug
the
readout
or
tum
off
the
circuit
breaker
providing
power
to
the
scale.
Press
and
hold
the
“ON”
pushbutton
to
switch
the
scale
"off.
Remove
the front
panel
of
the
readout
to
expose
the
battery.
Unplug
the
battery's
white
connector
from
the
power
supply
board
by
pulling
straight
up.
Remove
the
old
battery
from
its
holder
(it
may
be
taped
in
place)
and
install
the
new
battery.
Insert
the
new
battery's
connector
on
the
exposed
power
supply
pins.
Re-attach
the front
panel
and
restore
operating
power.
Turn
the
scale
back
on
by
pressing
the
“ON”
pushbutton
and
observe
that
the
front
panel
“CHARGE”
indicator
is
lit.
3.70
SPECIAL
PROGRAMMING
FEATURES
Your
SCALE-TRONIX®
second
generation
weighing
scale
incorporates
a
unique
feature
that
lets
you
"customize"
the
scale
to
best
suit
your
needs.
This
“set-
up"
mode
allows
the
characteristics
of
the
scale
to
match
your
particular
requirements.
liems
that
can
be
selected
include
the
automatic
shut-off
time,
weight
resolution,
weighing
units,
automatic
printing,
etc.
3.71
ENTERING
THE
"SET-UP"
MODE
To
enter
the
“set-up”
mode
start
with
the
scale
turned
off.
Note
the
small "ST"
logo
("ST")
located
directly
above
the
"RE
CALL"
pushbutton
on
the
front
panel
of
the
readout.
This
"ST"
actually
contains
a
small
hidden
pushbutton.
Press
and
hold
this
“ST"
pushbutton
on
the
front
panel
while
turning
the
power
on
with
the
“ON”
pushbutton.
(Use
the
rocker
power
switch
in
place
of
the
"ON"
button
on the
models
5102
and
6202.)
Once
the
scale
turns
on
release
the
"ST“
pushbutton,
then
press
and
release
it
5
more
times.
The
scale
will
display
"SE*UP"
and
produce
a
series
of
four
long
beeps.
“Set-up"
mode
has
now
been
entered.
The "RE
CALL"
pushbutton
is
used
to
select
the
particular
option
value.
Once
this
value
is
selected
the
scale
can
be
advanced
to
the
next
option
by
again
pressing
the
"ST
pushbutton
or
it
can
be
shut-off
by
pressing
and
holding
the
"ON"
pushbutton.
(Use
the
rocker
power
switch
in
place
of
the
"ON"
button
on the
models
5102
and
6202.)
When
the
scale
is
turned
back
on,
normal
scale
operation
will
then
resume
using
the
newly
programmed
features.
3.72
SETTING
THE
OPTIONS
First
enter
the
"SET-UP" mode
as
explained
above,
4)
Press
the
"ST"
pushbutton.
The
scale
will
display
“SOFf
(software
version).
Press
the
"ST"
5002,
5102, 5602,
6002,
6102,
6202, 6502,
6702
13