Thank you for choosing a Scalemaster Water Soener
Please take the me to read this installaon guide. It will tell you in simple terms how to install
and commission your new Scalemaster Water Soener to begin enjoying the benets of
soened water.
Before You Start
Before starng installaon, inspect the Water Soener for shipping damage or shortages.
Make sure you have all the necessary tools on hand before starng the installaon.
Follow all applicable Plumbing and Electrical regulaons when installing the Water Soener.
If in doubt, refer to the relevant WRAS Informaon and Guidance note at:
www.wras.co.uk/PDF_Files/ign9-07-01.pdf
This Water Soener is not intended for the treatment of water that is microbiologically
unsafe or of unknown quality without adequate disinfecon before or aer the Water
Soener and is to be used only for potable water.
Use cauon when installing soldered metal piping near the Water Soener. Heat can
adversely aect the plasc control valve or bypass valve system. Be sure all soldered pipes
are fully cooled before aaching plasc plumbing ngs.
Take care not to strip the threads when ghtening plasc pipe ngs. PTFE tape may be
used on connecons that do not use an Oring seal. Do not allow pipe joinng compound
or sealant to come into contact with any plasc parts.
There should be a minimum runo at least 3 meters of pipe between a soener and a water
heater to prevent the possibility of hot water entering the soener unit.
Use only the power transformer supplied with the Water Soener unit.
The mains power adapter supplied is double-insulated and does not require earthing. Earth
bonding should be applied across metal inlet and outlet pipework of the Water Soener to
maintain earth connuity.
Observe drain line requirements. The drain line must be a minimum of 12.5mm diameter.
The unit should be above, and not more than 6 metres from a drain.
Do not support the weight of the Water Soener on the control valve connecons or
plumbing.
Protect the soener, soener drain and all other components from the eects of frost.
Evidence of damage due to freezing will invalidate your Water Soener warranty.
Keep the media vessel in the upright posion. Do not turn upside down or drop. Turning the
vessel upside down or laying the vessel on its side can cause treatment media to enter the
valve.
If in doubt contact the Technical Helpline on 07990 064096
3