19
2019-03-06 / V1.0
Contactors CT/CU Series – Installation and Maintenance Instructions
Installation
Mechanical installation procedure
Remove the upper module
Depending on the contactor type, see Fig. 5 to Fig. 8.
X
Remove the upper module (A) from the lower
module (B).
In order to do so:
- Press the both release buttons (1) together with
one hand.
- With the other hand turn the 4 levers (2) down
one by one to unlatch the upper module (A).
- Lift up the upper module (A) and put in on a ta-
ble in an upright position.
A
1
2
2
B
Fig. 5: CT/CU 1115/04, 1130/04, 1115/08/10, 1130/08/10:
Remove the upper module (A) from the lower module
(B)
A
1
2
2
B
Fig. 6: CT/CU 1115/11, 1130/11: Remove the upper module
(A) from the lower module (B)
In case of double pole contactors:
X
Repeat the steps above with the second upper
module.
A
1
2
2
B
Fig. 7: CT/CU 1215/04, 1230/04, 1215/08/10, 1230/08/10:
Remove the upper module (A) from the lower module
(B)
A
1
2
B
2
Fig. 8: CT/CU 1215/11, 1230/11: Remove the upper module
(A) from the lower module (B)