Bedienungsanleitung
Operating Instructions
schuett phoenix II
eco – standard – accu
Sicherheits-Bunsenbrenner
Safety Bunsen Burner
Bitte lesen Sie die Bedienungsanleitung sorgfältig und bewahren Sie sie in der Nähe des Gerätes auf.
Please read this operating instruction carefully and keep it near the equipment.
Question and Answer IconNeed help?

Do you have a question about the Schuett Biotec Phoenix II and is the answer not in the manual?

Schuett Biotec Phoenix II Specifications

General IconGeneral
BrandSchuett Biotec
ModelPhoenix II
CategoryBurner
LanguageEnglish

Summary

Gas Supply Operations

Operation with Natural Gas

Connects the burner to natural gas supply using a DVGW-tested hose.

Operation with Propane/Butane Gas

Describes changing nozzles and connecting gas supply or cartridge adapter.

Operation with Cartridge Adapters

Details connecting adapters with pressure reducers and gas-safety hoses for cartridges.

Operating Times and Flame Control

Operating Time with Cartridge Types

Provides estimated burn times for CV 360 and C 206 cartridges.

Operation with Gas Bottles

Instructions for connecting the burner to larger gas bottles via a hose.

Flame Setting and Adjustment

Guides on adjusting gas and air supply for different flame types.

Phoenix II eco Functions

Operating Mode "Hand"

Activates flame by pressing joystick center; burns until time elapses or stopped.

Operating Mode "Foot-switch"

Activates flame by pressing the foot-switch; burns only while pressed.

Power Indicator Lamp Status

Explains meanings of Red, Flashing Red/Yellow, and Flashing Red lights.

Operating Modes (Standard, Accu)

Operating Mode "Hand"

Flame activated by joystick, burns until preset time elapses or stopped.

Operating Mode "Foot"

Activates flame via foot-switch, with burn-time display or continuous activation.

Operating Mode "Sensor"

Activates burner via hand/body movement in front of the sensor.

Burn-time Setting and Battery Information

Setting the Burn-time

Adjusts preset burn-time using joystick, displays time in seconds/minutes.

Information on Battery (phoenix II accu)

Instructions for charging, using, and handling the device's battery.

Sensor Function Settings

Setting "Sensor Activation"

Configures sensor to activate flame with one or two movements.

Setting "Sensor Sensitivity"

Adjusts sensor responsiveness from off to high sensitivity up to 8 cm.

Setting "Sensor Turns Off Flame"

Configures if the sensor should turn off the flame with a movement.

General Settings

Setup Level "Language"

Selects the display language for the device interface.

Setup Level "Automatic Shut Down"

Sets the time after which the device automatically switches off if not used.

Setup Level "Reset to Default Settings"

Resets all user configurations to factory default values.

Display Messages and Warnings

Ignition Control: "Check Gas Supply"

Message indicating a problem with gas supply during ignition.

Burner Control: "Clean Burner Head"

Message indicating the burner head needs cleaning after flame extinguishes.

Warning: "Hot Burner Head"

Alerts user to a hot burner head, cautioning against touching.

Warning: "Burner Overheated"

Indicates the burner has become too hot and automatically shut off.

Error Messages and Safety Measures

"'Switch on sensor' Message"

Appears if sensor sensitivity is set to 'off' when selecting sensor mode.

"'Plug in foot-switch' Message"

Appears if foot-switch is not connected when selecting 'Foot' mode.

"'Charge battery' Message"

Indicates the battery voltage is low and requires charging.

Constructive Safety Measures

Details design features for safety like low burner tube and overheating protection.

Cleaning and Service

Cleaning the Safety Bunsen Burner

Instructions for cleaning the burner body with mild agents.

Cleaning the Burner Head

Details on removing, cleaning (dishwasher), and reattaching the burner head.

Service and Annual Inspection

Recommendations for regular checks of seals, cables, and hoses.

Troubleshooting Guide

Blank Display or No Response

Checks line/mains connections, voltage, and cable connections.

No Flame / Check Gas Supply Error

Addresses issues with gas supply, empty cartridges, or incorrect nozzle.

Flame Size or Stability Issues

Guides on optimizing gas/air mixture and nozzle selection.

Sensor or Foot-switch Malfunctions

Troubleshooting steps for unresponsive sensors or foot-switches.

Technical Specifications

Burn-time and Voltage Data

Lists adjustable burn-time range and power supply voltage.

Gas Pressure and Heat Load

Details working pressures and rated heat loads for different gases.

Consumption and Dimensions

Provides gas consumption rates and physical dimensions/weight.

Default Settings Overview

Outlines factory default language, operating mode, and burn-time settings.

Accessories and Spare Parts

Foot-switch and Protective Accessories

Lists optional accessories like foot-switches and protective guards.

Burner Heads and Power Supplies

Details replacement burner heads, power units, and adapters.

Gas Hoses and Cartridge Adapters

Information on different types of hoses and adapters for gas cartridges.

Gas Cartridges

Lists available gas cartridges with specifications like type, weight, and quantity.