EasyManua.ls Logo

Schwing SP 750-18 - Cable Remote Functions; Radio Remote (Optional)

Default Icon
158 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
156
Short Instructions
SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual
Cable Remote Functions
The cable remote includes the following buttons:
A. E-Stop Button
B. Horn
C. Concrete Pump Forward
D. Stroke Limiter (+)
E. Throttle (+)
F. Concrete Pump - O󰀨
G. Stroke Limiter (-)
H. Throttle (-)
I. Concrete Pump - Reverse
J. Vibrator Auto/Manual - On/O󰀨
K. Agitator - On/O󰀨
L. Optional Accessories 1 - On/O󰀨
M. Optional Accessories 2 - On/O󰀨
ACC2ACC1
ACC2ACC1
A
B
E
H
K
C
D
G
F
I
J
L M
Radio Remote (Optional)
To use the wireless remote, remove the dummy or ca-
ble remote plug from the socket and install the receiver
plug. At the operator control panel, put the Local/Re-
mote button in the remote position. On the wireless re-
mote, unlock the E-stop button by turning it clockwise.
Press the Power ON button and then press the horn
button. If the transmitter’s signal light does not ash,
check the battery orientation.
To turn o󰀨 the transmitter, press the Power OFF button
or the E-Stop button.
Dummy Plug
Horn Button
E-stop Button
Power ON
Button
Power OFF
Button
Dummy Plug
(removed)
Wireless Remote Plug
50%
100%
Figure 6
Connecting the wireless remote

Table of Contents

Related product manuals