37
Overview
SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual
Warning Horn
A warning horn is mounted on the stroke limiter valve,
at the rear of the engine. It can be activated manually or
when an SCT warning message is displayed, such as
high oil temperature.
Warning Horn
Stroke Limiter Valve
Figure 9
Warning horn mounted on stroke limiter valve
Manual Activation
The horn can be manually sounded by press-
ing any horn button. Horn buttons are located
on the cable and radio remote as well as on the pas-
senger side of the hopper.
SCT Warning Message
When a warning message is displayed, the
horn will beep continuously, until the horn si-
lence button is pressed on the HMI panel.
Reset Procedure
The horn must be sounded to reset the machine after
an emergency stop button is reset.