45
Overview
SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual
Warning Messages
The Message Center will ash through all E-stop and
warning messages that are present. When a warning
message is displayed, the horn will beep continuously,
until the Horn Silence button is pressed on the HMI. The
horn will shut o, but the message will remain until the
fault is corrected.
E-stop Warnings
Warning Message Description
LEFT E-STOP Left side hopper E-Stop is pressed
RIGHT E-STOP Right side hopper E-Stop is pressed
WATERBOX E-STOP Waterbox E-Stop is pressed
REMOTE E-STOP Remote E-Stop is pressed
GRATE OPEN Hopper grate is open
RESET REQUEST Press Horn button on the Operator Panel or Remote to reset. The horn but-
ton next to the hopper will not reset the E-stop
General Warnings
Warning Message Description
LOW FUEL If enabled - Fuel level below 10%
LOW GREASE If enabled - Grease in pot below sensor
PUMP FAULT Check Pump Codes screen
LOW HYD OIL If enabled - Oil level is below oil level sensor
LOW BATTERY Battery is below 10 volts
HYD OIL TEMP If enabled - Temperature is above alarm set point
ENGINE FAULT Check Engine Codes screen
RAM CHANGE MODE Disables the Operator Panel and Remote controls. Idle goes to minimum,
strokes go to minimum.
%s
%s
ok
Navigation Pane
Horn Silence Symbol
Horn Silence Button