53
Overview
SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual
Cable Remote
The cable remote includes the following buttons:
A. E-Stop Button
B. Horn
C. Concrete Pump Forward
D. Stroke Limiter (+)
E. Throttle (+)
F. Concrete Pump - O
G. Stroke Limiter (-)
H. Throttle (-)
I. Concrete Pump - Reverse
J. Vibrator Auto/Manual - On/O
K. Agitator - On/O
L. Optional Accessories 1 - On/O
M. Optional Accessories 2 - On/O
ACC2ACC1
ACC2ACC1
A
C
D
G
F
I
J
L M
Keypad Buttons
E-Stop Button
Pushing the Emergency Stop Switch (E-Stop button)
disables the hydraulic circuit.
To reset the system and enable the hydraulic circuit, turn
the E-Stop button clockwise and press the horn button
on the cable or radio remote.
Concrete Pump - Forward
Puts the concrete pump into forward. This is called the
pumping position. Press once to put the concrete pump
in forward. Press and hold to change from pump re-
verse to pump forward.
= Inactive
= Pump/Forward
Concrete Pump - O
Stops the concrete pump. Press once shut the concrete
pump o.
= Inactive
= Pump/Off
Concrete Pump - Reverse
Puts the concrete pump in the reverse. This is typically
used for cleaning out or unclogging jams in the pipe-
line. Press once to put the concrete pump in reverse.
Press and hold to change from pump forward to pump
reverse.
= Inactive
= Pump/Reverse