XFp Extracellular Flux Analyzer
User Manual
Part #102745-400 Rev A
Question and Answer IconNeed help?

Do you have a question about the Seahorse XFp and is the answer not in the manual?

Seahorse XFp Specifications

General IconGeneral
TechnologyExtracellular Flux Analysis
MeasuresOxygen consumption rate (OCR) and extracellular acidification rate (ECAR)
Injection Ports4
Sample Throughput8 samples per run
ApplicationCell metabolism studies, mitochondrial function, glycolysis
Sample FormatAdherent cells or suspension cells in a microplate
Sample Volume180 µL per well (recommended)
Well Plate Format8-well miniplate
Software CompatibilityWave software

Summary

XFp Analyzer Overview

Technical Specifications

XFp Analyzer Installation

Unpacking and Component Identification

Verifies all included items are present and checks for shipping damage.

Suitable Locations for the XFp Analyzer

Guidelines for placing the analyzer in a suitable laboratory environment.

Safety Considerations

Critical warnings and precautions for safe operation of the instrument.

Basic Operation of the XFp Analyzer

Powering On and Warm-Up

Procedure for powering the instrument on and allowing it to reach operational temperature.

Initial Power-Up and Welcome Screen

Steps for the first-time power-up and initial diagnostic tests.

Network Connection Setup

Instructions for connecting the analyzer to a network for file transfer and support.

Turning the XFp Analyzer Off

Correct procedure for shutting down the instrument completely.

Navigating the XFp Analyzer

Setting up an XFp Assay

Steps to configure and start an assay on the analyzer.

Verifying Groups and Plate Map

Instructions for confirming assay groups and plate layout settings.

Reviewing and Editing the Instrument Protocol

Guide to checking and modifying assay protocol steps and cycles.

Reviewing Summary and Starting the Assay

Process for reviewing assay details and initiating the analysis.

Running the XFp Assay Procedure

Procedure for loading components and starting the assay calibration.

Interpreting Acquired Data Views

Explains how to view and interpret acquired OCR and ECAR data.

Completing the Assay and Saving Results

Steps for finishing the assay and ensuring data is saved correctly.

Modifying XFp Analyzer Settings

Environmental Settings Configuration

Configure temperature tolerance, alarms, and atmospheric pressure.

Backup Assay Results Management

Save copies of assay performance within the last 60 days to storage.

Auto Assay Naming Setup

Define the default naming convention for assay result files.

Template Management

Transfer assay template files between the analyzer and a Windows computer.

Device Settings Configuration

Guides configuration of network and other device settings.

XFp Analyzer Diagnostics

Diagnostic Tests

Perform system checks, measurement system tests, thermal performance, and advanced measurements.

Consumable Check and Injection Test

Verify barcode reading, calibration, and injection system performance.

Remote Assistance Setup

Enable remote access for technical support.

Maintenance Procedures

Covers probe cleaning, tray and probe movement, and cartridge eject/load.

Online Help & Support

Support Contact Information

Provides worldwide contact details for Seahorse Support.

Software/Hardware Version & Updates

Displays installed software and firmware versions; checks for updates.

Contextual Help Access

How to access help text related to the current screen.

Analyzing XFp Data with Wave for Desktop

Appendix I - Networking Guide

XFp System Network Information

Details integrated Ethernet adapter and approved Wi-Fi adapters.

Hardware Connection Options

Guides connection via Ethernet cable or wireless USB adapter.

Wired Network Setup Procedure

Steps to configure wired network connection using IP address assignment.

Wireless Network Setup Procedure

Steps to connect the analyzer to a wireless network using a USB adapter.

Shared Folder and Network Directory Setup

Configure network directory for saving templates and results.

Email and Time Settings Configuration

Configure email notifications and synchronize date/time settings.

Appendix II - Troubleshooting

Template Page Display Delay

Troubleshoot slow appearance of the template page due to network issues.

Instrument Load Error Resolution

Resolve "load error" messages related to cartridge status.

Appendix III - Support Contact and Ordering

Product Questions and Technical Support

Contact information for product inquiries and technical support.

Consumables and Supply Ordering

Details on how to order XFp FluxPaks and other supplies.