Liberty 100 Smart Electricity Meter Technical Reference Manual
Diagnostic Displays in Prepayment Mode
Key 9: UTRN history
Title 1: Number of accepted UTRNs
(timeout 2 secs)
Followed by value
(timeout 4 secs)
Press key 9 to advance to the next display.
The 1
st
set of displays associated with key 9 displays
the number of UTRNs accepted.
The example shows that the meter has accepted 16
UTRNs since manufacture.
Title 2: Number of rejected UTRNs
(timeout 2 secs)
Followed by value
(timeout 4 secs)
Press key 9 to advance to the next display.
The 2
nd
set displays the number of UTRNs rejected.
The example shows that the meter has rejected 16
UTRNs since manufacture.
Title 3: Vend UTRN Details
Or
(timeout 2 secs)
Followed by Subtitle: Vend 1 transaction
(timeout 2 secs)
Followed by vend amount
(timeout 2 secs)
Followed by vend date
(timeout 2 secs)
The 3
rd
set displays ‘No UTRN’ if there are no vend
UTRNs. If there are vend UTRNs then it shows the
vend UTRN transaction details such as vend amount,
vend date, vending time and the UTRN number. The
list displays the last five (5) historical UTRN details.
The example shows the following displays:
Vend 1 Meter Transaction is the latest vend UTRN.
£11.78 is the vend amount.
02/03/2014 is vend input date.
00:32:10 is vend input time.