Common attributes:
Access Types = Read/ Write
Size Bytes = 1, Min Value = 0, Max Value = 255
Zero configuration mean that the corresponding
functionality is disabled.
Configuration value = Desired value/ Resolution.
Example: To configure Delta temperature to 2 °C. The
value need to be configured in device is 2/0.1 = 20.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range
128…255, the value sent in the application shall be equal
to desired value minus 256. For example, to set Delta
Temperature to 130, it may be needed to set a value
130−256=−126.
Note: For more information about Z-Wave command
classes and their use refer “SDS12652 Z-Wave
Command Class Specification” ver 3 or above and
“SDS12657 Z-Wave Command Class Specification” ver 2
or above.