17
TROUBLESHOOTING
142
17-3 REPLACING FUSES
• Neverreplaceafusewithanythingotherthandesignatedfuse.Otherwisethere
could be accidents. In case fuse replacements other than those stated in this
manual are necessary, contact where you purchased the product from for
inquiries regarding this matter.
In order to prevent an electric shock, be sure to turn power off and unplug from
the socket outlet before performing work by touching the internal parts of the
product.
Be careful so as not to damage wiring. Damaged wiring can cause electric
shock and short circuit accidents.
Be sure to use fuses meeting specified rating. Using fuses exceeding the
speciedratingcancausereandelectricshockaccidents.
After eliminating the cause of the blowing of fuse, replace the fuse. Depending
on the cause of fuse blowing, continued use with the fuse as is blown can cause
generationofheatandrehazard.
There are 2 fuses deep within the AC unit in the base. They are to the left as you face the monitor (CRT). If there
is only enough space for ventilation, cut off the power supply and move the product to secure enough space for
working. Since various situations are possible, this manual does not discuss factors that may cause each specic fuse
to melt.
1
Turn the main switch to OFF and remove the power plug from the outlet.
2
Remove 2 truss screws that hold down the front door on the left side of the base.