Check the operation of the switches and connectors connected to the SystemSP board.
(A) Change from OFF to ON when the SW1 and SW2 switches on the SystemSP board are
operated.
(B) Change from OFF to ON when the TEST, SERVICE, COIN1 and COIN2 switches are
operated.
(C) Change from OFF to ON when the COIN1 and COIN2 switches are operated.
(D) Changes from 1 to 0 when the switch connected to pin 17 to pin 24 of the CN9 is operated.
(E) Changes from 1 to 0 when the switch connected to pin 41 to pin 48 of the CN9 is operated.
(F) Changes from 1 to 0 when the DIP switch (SW3) or push switch (SW1, SW2) on the
SystemSP board or the switch connected to pin 5 or pin 6 of the CN9 are operated.
(G) Changes from 1 to 0 when the switch connected to pin 9 to pin 16 of the CN10 is operated.
The “1” and “0” display for (D) to (G) differs depending upon the game title.
Press the TEST Button and SERVICE Button to return to the System Menu screen.
This mode allows a sound output test to be performed. A beep will be produced from each speaker.
Press the SERVICE Button to move the cursor.
Move the cursor to your desired selection and press the TEST Button.
Move the cursor to EXIT and press the TEST Button to return to the System Menu screen.
(A) RIGHT/LEFT SPEAKER (ON/OFF)
Turn this option “ON” to produce a beeping noise from that speaker.
I/O TEST
SW1 OFF (A)
SW2 OFF (A)
TEST OFF (B)
SERVICE OFF (B)
COIN1 OFF (B)
COIN2 OFF (B)
COIN METER1 OFF (C)
COIN METER2 OFF (C)
IN_PORT0 11111111 (D)
IN_PORT1 11111111 (E)
IN_PORT2 11110011 (F)
G_PORT 11111111 (G)
PRESS TEST AND SERVICE BUTTON TO EXIT
SOUND TEST
RIGHT SPEAKER OFF (A)
LEFT SPEAKER OFF (A)
->EXIT
SELECT WITH SERVICE BUTTON
AND PRESS TEST BUTTON
D. I/O TEST
E. SOUND TEST
NOTE:Only the LEFT SPEAKER is tting with a service door for this game.