TROUBLESHOOTING TABLE
PROBLEMS CAUSE COUNTERMEASURES
With main switch ON, no
activation.
Power is not supplied. Securely insert the power plug into the plug
socket.
Power supply/voltage is not
correct.
Make sure that power supply/voltage is correct.
The circuit protector functioned
due to the momentary overload.
After eliminating the cause of overload,
reinstate the AC unit’s circuit protector.
(Wait at least 1 minute and then press the
button.) (See “Circuit Protector ” on the next
page.)
Billboard does not light up. The wiring is not connected
correctly.
Check the connections of the wiring between
the cabinet and billboard.
Fluorescent lamp and glow lamp
need replacement.
Replace the uorescent lamp and the glow
lamp. (See Chapter 16.)
Sound does not output from
speakers.
Volume is not adjusted properly. Adjust the volume on the switch unit.
(See Chapter 9.)
Faulty connections for various
connectors.
Check the connections for the game board,
amp, speakers and volume connectors.
Malfunctioning BD, amp and
speaker.
Perform SPEAKER TEST. (See SYSTEM
TEST MODE in RINGWIDE Service Manual.)
Sounds are emitted and the
lamps are lit, but the screen is
black.
Faulty connections for the visual
signal connector or the monitor
power connector.
Check the connections for the monitor and
game board connectors.
Broken monitor. Contact the point-of-purchase for this product.
Colors on the monitor screen
are strange.
Faulty connection for the visual
signal connector.
Check the visual signal connector connection
and make sure it is secured properly.
Screen adjustment is not
appropriate.
Make adjustment appropriately.
(See Chapter 10.)
Does not accept input from
any switch or volume.
Faulty connector connections. Check the connection for the I/O board and
cabinet connector.
Check the power for the I/O board.
Does not accept input from
the shift lever.
Faulty connector connections. Check the connections for the connectors in
the control panel and between the control panel
and the cabinet.
Broken Microswitch. Replace the Microswitch.
(See 12-2, Microswitch: 509-5704)
Steering (Servomotor)
response is incorrect.
Failure of power-on checking
procedure.
Power on and verify that the power on check
completes properly. (See 6-4.)
Faulty volume attachment or
adjust gear alignment.
Adjust the volume attachment and verify in
TEST MODE. (See Chapter 9, 11.)
Volume malfunctioning. Replace the volume. (See 11-2, Volume:
220-5753.)
Detached wires. Check for faulty wire connections around
moving parts.
When replacing wires, fasten them in place so
that they do not come in contact with moving
parts.