DISPLAY Error 1000
Force Feedback Error
CAUSE Failed to initialise motor controller during power on cycle.
COUNTERMEASURES Check all connection to and from Motor Controller.
Possible failure of Motor Controller PCB. Replace and restart.
DISPLAY <TICKET ERROR> PLEASE CONTACT OPERATOR
CAUSE Ticket has jammed or tickets are empty.
COUNTERMEASURES Clear ticket jam. Reoat with new tickets.
Note: When resetting the error message, please take note of the number of
tickets owed to the player as this number of tickets cannot be recalled.
DISPLAY ,<NETWORK FAILURE> PLEASE CONTACT OPERATOR
CAUSE Communication failure across the network.
COUNTERMEASURES Check all network cables for damage. Check all network connections to
Hub. Check Hub for power. Possible Hub failure.
DISPLAY <NETWORK FAILURE> <CABINET ID CONFLICT> PLEASE CONTACT OPERATOR
CAUSE Incorrect values given to individual cabinets across the network.
COUNTERMEASRES See chapter 9-3-4 on setting cabinet identications
Other ERROR codes.