ARM MECHANISM
13
LIMITS ON FORWARD/BACKWARD MOVEMENT OF UFO MECHANISM
To limit the range in which the UFO mechanism can be moved forward/backward, change the position of the sensor
bracket limit. The UFO mechanism stops where the sensor bracket limit is located.
PHOTO
13-2e
PHOTO
13-2f
1. Loosen the wing screw at the rear of the Y-oriented
mechanism.
2. Move the sensor bracket limit to the desired location
and tighten the wing screw.
The sensor bracket limit positions and areas where the UFO mechanism cannot be moved to are as shown in the
illustration.
FIG. 13-2c