Section 2: Preflight Safety Check
Bambi Bucket Operations Manual 4
13. With power on, check the function of the pumps by pressing the pump’s ON button for four
or five seconds.
The pump should turn on and run for the period the button is held. The pump will be
audible within a few feet of the bucket.
Listen for abnormal noises that are not consistent with smooth operation. If you are
operating in a noisy environment, you can confirm that the pump is running by holding
your hand on the top of the filter screen.
You may also see the shell move each time you activate the switch.
14. Check the filter screen for debris accumulation and clear as necessary.
15. Check the filter screen for signs of damage that may affect water flow.
16. Repair any damage to the components above before operating.
CAUTION
Do not put your fingers or other objects into the pump impeller while the pump is running. Personal
injury or damage to the pump can occur.