Schweitzer Engineering Laboratories, Inc. SEL-2241 Data Sheet
Each SEL Axion
®
system requires an RTAC module to serve as the system CPU. The SEL-2241 RTAC has all of the
communications and custom logic capabilities of the standalone RTAC modules, but is mounted in and receives power
from the Axion backplane.
Front-Panel
The following figure shows the RTAC status LEDs that
aid system troubleshooting and the connectors for com-
munications and wiring.
Figure 1 SEL-2241 RTAC Front Panel, Copper Ethernet
Mechanical Installation
Each SEL-2242 chassis/backplane has ten slots, labeled
A through J. Only Slot A supports the SEL-2241 RTAC
module.
To install the RTAC, tip the top of the module away from
the chassis, align the notch on the bottom of the module
with Slot A of the chassis, and place the module on the
bottom lip of the chassis as Figure 2 illustrates. The
module is aligned properly when it rests entirely on the
lip of the chassis.
Figure 2 Proper Module Placement
Next, carefully rotate the module into the chassis, mak-
ing sure that the alignment pin fits into the corresponding
slot at the top of the chassis (refer to Figure 3). Finally,
press the module firmly into the chassis and tighten the
chassis retaining screw.
SEL-2241 Real-Time Automation
Controller (RTAC)
Question and Answer IconNeed help?

Do you have a question about the Sel SEL-2241 and is the answer not in the manual?

Sel SEL-2241 Specifications

General IconGeneral
ModelSEL-2241
CategoryController
Input Voltage12/24 Vdc
Communication PortsEthernet, Serial
Operating Temperature-40°C to +85°C
ProtectionIP20
MountingDIN rail
ManufacturerSchweitzer Engineering Laboratories

Summary

Front-Panel

Mechanical Installation

Instructions for installing the RTAC module into the chassis.

Connections

Communications Ports

Details on how to connect the RTAC via Ethernet and USB.

Outputs and Module Replacement

Status Indicators and Field Service

Information on RTAC status LEDs and field serviceability.

Real-Time Clock Battery Replacement

Steps for replacing the real-time clock battery.

SEL-2241 Module Handling and Jumpers

Disassembly and Reassembly

Steps for disassembling and reassembling the SEL-2241 RTAC.

Configurable Jumper Positions

Details on configurable jumper positions for the RTAC.

Specifications

Compliance

Standards and certifications the product adheres to.

General Operating Environment

Operating temperature range and environmental conditions.

Dimensions and Weight

Physical dimensions and weight of the RTAC module.

CPU and Memory

Processor speed and memory specifications for the RTAC.

Security Features

Account management and intrusion detection capabilities.

Automation Protocols

Supported communication protocols for automation tasks.

Ethernet Ports

Details on Ethernet ports for backplane and terminal connections.

Specifications - Ports and Outputs

Serial and USB Ports

Specifications for serial and USB port types and data rates.

Output Contact Ratings

Mechanical durability and contact ratings for output terminals.

DC and AC Output Ratings

Voltage and current ratings for DC and AC output contacts.

Type Tests

Summary of environmental, dielectric, and RFI tests performed.

Specifications - Emissions

Emissions

Details on radiated and conducted emissions compliance.

Related product manuals