Do you have a question about the Sellstrom S90320 Gravit-Eye and is the answer not in the manual?
Brand | Sellstrom |
---|---|
Model | S90320 Gravit-Eye |
Category | Security Sensors |
Language | English |
The Gravit-Eye® is approved solely as an emergency eyewash station, requiring maintained water purity.
Position nozzles 33-45 inches high, 6 inches from walls, ensuring proper fluid drainage.
Surface must support 155 lbs filled weight with a 2:1 safety factor (310 lbs static load).
Use enclosed 'J' bracket, ensure wall construction supports unit weight securely.
Do not mount into drywall without a wood stud for adequate weight support.
Protect from freezing; deliver tepid water (60-100°F). Consult advisor for chemical reaction temps.
Activate eyewash for 5 seconds to visually verify flow after installation.
Ensure area has a highly visible sign and is well lit for eyewash accessibility.
Clean and rinse station. Fill with hot water (140F/60C) or hotter before initial use.
Clean and rinse the unit every time it is filled for hygiene.
Partially fill with potable water, then add bacteriostatic additive before topping up.
Add one 8oz bottle of additive to prevent bacteria growth in the tank.
Fill the tank to 1/8-inch below the overflow point.
Install the cap on top of the station but do not overtighten.
Replace water and clean eyewash station at least every six months.
Read and follow all instructions to prevent serious eye damage and vision loss.
Clean tank every six months. Refill using hot water (140F/60C) and add bacteriostatic additive.
Inspect weekly for adequate water level. Replace water immediately if particulates or discoloration are found.