Do you have a question about the Sentinel 880 Sigma 130Ci and is the answer not in the manual?
Warnings regarding unqualified personnel, radiation dangers, and source handling.
Principles of TIME, DISTANCE, and SHIELDING for minimizing exposure.
Safety measures, instruments, area control, distance, and shielding guidelines.
Procedures for monitoring operations and securing the device when not in use.
Lists critical steps and details on surveying the exposure device.
Warning about cable length and conduit layout instructions.
Verifying connections, personnel location, signs, and handling cautions.
Steps for unlocking the device and preparing the selector ring.
Procedures for projecting the source assembly using the control crank.
Procedures for retracting the source assembly and securing the device.
Performing post-exposure surveys and locking the device.
Steps for inspecting the exposure device, labels, and source guide tubes.
Detailed inspection of control crank, cable, conduits, and connectors.
Using NO GO gauge for wear on connectors and ensuring cable movement.
Specific inspection points for the exposure device, including radiation levels and labels.
Steps for annual maintenance, source transfer, and leak testing.
Instructions for reassembling and functionally testing the locking mechanism.
Reassembling the device and testing the system with mock source.
Specific checks for control crank, conduits, and cable anomalies.
Steps and risks associated with testing the locking system's integrity.
Steps to follow if the source assembly cannot be returned to the shielded position.
Requirements for boundaries, signs, area classifications, and monitoring.