Important Installation and Usage Guidelines

Correct Installation and Service Requirements

Proper installation ensures function and warranty. Regular service is indicated on the toilet display.

Proper Usage for Optimal Function

Use specified bags, burn only urine, solid waste, and paper. Use correct programs for energy savings.

Ventilation System Requirements

Prohibition of Other Ventilation Systems

Ensure no other ventilation systems, like fans, are present in the installation space.

Installation Components and Airflow

Mandatory 90° Bend and Vent Cowl

Install the included 90° bend and vent cowl for optimal airflow; using alternatives voids the warranty.

Sealing Components

O-Ring Functionality

O-rings seal the connection between the toilet and vent tube, preventing air and odor leaks.

Ventilation Airflow Distances

Minimum Distance for Air Intake and Outlet

Maintain a minimum 3-4 meter distance between air intake and vent outlet to prevent re-circulation.

Ventilation Pipe Installation Details

Connection Pipe and Length Limits

Use the supplied 100mm pipe; total length from 90° bend max 5m. Max 500mm above roof.

Condensation Drainage and Air Valve Placement

Attach hose for condensation. Fresh air valve on outer wall, min 160mm Ø.

Installation Restrictions

Only Ø110mm pipes and one 90° bend allowed. 30cm space needed for rear 90° bend installation.

Detailed Ventilation Installation Specifications

Connection Pipe and Inclination

Install horizontal connection pipe max 500mm with 2° backward inclination, min 100mm from wall.

Total Length and Bend Limitations

Total length from 90° bend max 4.5m. Max 500mm between 45° bends. Max 500mm above roof.

Ventilation Valve Placement and Pipe Requirements

Ventilation valve on outer wall (min 110/160mm Ø). Only Ø110mm pipes and one 90° bend allowed.