Manual – Fieldbus Interface INTERBUS UFI11A
INTERBUS Interface
Use the following table for the valid settings. You can also refer to the example settings
given below if you are operating the fieldbus interface in Autosetup mode.
The UFI11A signals the "Microprocessor not ready" ID code (38h) if the settings of DIP
switches S1-1 to S1-7 are invalid.
Number of process data words 0 PCP words 1 PCP word 2 PCP words 4 PCP words
1 XXXX
2 XXXX
3 XXXX
4 XXXX
5 XXXX
6 XXXX
7 XXX
8 XXXX
9XX
10 X X X
11 X
12 X X X
13 X
14 X X
15 X
16 X
17
18
19
20 X
21
22 XX
23 X
24 X X
De-energize the UFI11A before adjusting the DIP switch settings. The settings of DIP
switches S1-1 to S1-7 are only read during the power-up initialization.