10
58
Manual – Fieldbus Interface INTERBUS UFI11A
Parameter List
10 Parameter List
Par.
no.
Parameter Index Unit Access Default Meaning / Value range
010 Unit status 8310 RO 0
011 Operating status 8310 RO 0
012 Error status 8310 RO 0
013 Current parameter set 8310 RO 0
015 Operating hours 8328 s RO/N 0
070 Device type 8301 RO 0
076 Firmware basic unit 8300 RO 0
090 PD – configuration 8451 RO 4
091 Fieldbus type 8452 RO 2
092 Baud rate fieldbus 8453 RO 0
093 Fieldbus address 8454 RO 0
094 PO1 setpoint 8455 RO 0
095 PO2 setpoint 8456 RO 0
096 PO3 setpoint 8457 RO 0
097 PI1 actual value 8458 RO 0
098 PI2 actual value 8459 RO 0
099 PI3 actual value 8460 RO 0
802 Factory setting 8594 R/RW 0 0: NO
1: YES
2: DELIVERY STATUS
810 RS485 address 8597 R0 0
812 RS485 timeout delay 8599 s R/RW 1
816 SBUS Baud rate 8603 R/RW 0 0: 125 kBaud
1: 250 kBaud
2: 500 kBaud
3: 1000 kBaud
819 Fieldbus timeout delay 8606 s RO 0.630
831 RESPONSE fieldbus timeout 8610 R/RW 10 0: NO RESPONSE
10: PO DATA = 0 / WARN
840 Manual reset 8617 R/RW
870 Setpoint description PO1 8304 RO 12 IPOS PO DATA
871 Setpoint description PO2 8305 RO 12 IPOS PO DATA
872 Setpoint description PO3 8306 RO 12 IPOS PO DATA
873 Acutal value description PI1 8307 RO 9 IPOS PI DATA
874 Actual value description PI2 8308 RO 9 IPOS PI DATA
875 Actual value description PI3 8309 RO 9 IPOS PI DATA