14
Service
Extended storage
Manual – EtherCAT
®
Interfaces, Field Distributors
118
14.4.2 Replacing the device
WARNING
Electric shock caused by dangerous voltages in the connection box. Dangerous
voltages may still be present for up to 1 minute after disconnection from the supply
system.
Severe or fatal injuries.
De-energize the MOVIMOT
®
drive using a suitable cut-off device before remov-
ing the MOVIMOT
®
inverter.
Secure the drive against unintended re-connection to the voltage supply.
Wait for at least 1 minute before removing the MOVIMOT
®
inverter.
Replace the MFE fieldbus interface as follows:
1. Loosen the retaining screw and remove the MFE fieldbus interface from the field
distributor.
2. Set DIP switches S1/1 to S1/4 on the new MFE fieldbus interface to the same set-
tings as the DIP switches on the old MFE fieldbus interface.
3. Set the new MFE fieldbus interface on the field distributor.
Fasten the MFE fieldbus interface with 4 screws to the field distributor.
4. Connect the field distributor to the new MFE fieldbus interface.
14.4.3 MOVIMOT
®
device replacement
INFORMATION
For information on the device replacement of the MOVIMOT
®
inverter, refer to the
"MOVIMOT
®
MM..D" operating instructions.
14.5 Extended storage
If a unit with inverter is being stored for a long time, connect it to the mains voltage for
at least 5 minutes every 2 years. Otherwise, the service life of the unit may be re-
duced.