5
Mechanical installation
Tightening torques
Manual – EtherCAT
®
Interfaces, Field Distributors
26
Tighten EMC cable glands supplied by SEW‑EURODRIVE using the following torque
ratings:
Screw fitting Tightening torque
M12×1.5 2.5Nm–3.5Nm
M16×1.5 3.0Nm–4.0Nm
M20×1.5 3.5Nm–5.0Nm
M25×1.5 4.0Nm–5.5Nm
The cable retention in the cable gland must be able to withstand the following removal
force:
Cable with outer diameter >10mm: ≥ 160N
Cable with outer diameter <10mm: = 100N
5.2.5 Motor cable
9007200393364491
Tighten screws for motor cables using 1.2–1.8Nm.