11
Supplementary field distributor startup information
MOVIMOT® inverter integrated in field distributor
Manual – EtherCAT
®
Interfaces, Field Distributors
89
11.3.3 Internal wiring of the MOVIMOT
®
inverter in the field distributor
24V
TH
L
R
13
14
15
L1
L2
L3
L1
L2
L3
24 V
TH
[4]
[1]
[2]
[3]
X4
ϑ
9007200441675147
[1] DIP switches for setting the connection type (W or m)
Make sure that the connection type of the connected motor corresponds
with the setting of the DIP switch.
[2] Note the enabled direction of rotation
(Both directions of rotation are enabled as standard)
Both directions of rota-
tion are enabled
Only CCW direction of
rotation is enabled
Only CW direction of rotation is
enabled
24V
TH
L
R
24V
TH
L
R
24V
TH
L
R
TH
TH
TH
ϑ
ϑ ϑ
[3] Connection for internal braking resistor (in motors without brake only)
[4] Maintenance switch
11.4 MOVIMOT
®
inverter integrated in field distributor
MOVIMOT®
inverter
integrated
in field
distributor
The following chapter describes the differences in the use of the MOVIMOT
®
inverter
integrated in the field distributor compared to use when it is integrated in the motor.
11.4.1 Different factory settings for MOVIMOT
®
integrated in the field distributor
Note the changes to the factory settings (in bold) when using MOVIMOT
®
integrated in
Z.7. or Z.8 field distributors:
DIP switch S1
S1 1 2 3 4
Meaning RS485 address
2
0
2
1
2
2
2
3
MOVIMOT
®
1 ON 1 1 1 1
OFF 0 0 0 0
25809148/EN – 01/2019