41
13VT-R100/R150
13VT-CR10
Measuring Monitor screen
instrument
Mode EP still picture playback
Input signal Self-recording tape
Test point Monitor screen
Control CH '/" (TR ±/ ) buttons
Specification No Vertical jitter
1. Play back the EP Self-recorded tape in the still mode.
2. Using the CH '/" (TR ±/ ) buttons on the remote
control or on the front pannel, make adjustment so that
the vertical jitter becomes minimum.
3. Then press the STOP button to stop the tape.
Note:
The data of this adjustment is memorized to the E
2
P-ROM
IC.
ADJUSTMENT OF STILL PICTURE
VERTICAL SYNC
Figure 2-2.
Ë Test points layout of Main Unit.