30
AH-A07BE-C/09BE-C
AH-A07BE/09BE/12BE
AY-A07BE-C/09BE-C
AY-A07BE/09BE/12BE
Indoor side
Standard conditions:
Dry-bulb Temp. (˚C) Relative Humidity (%)
27Cooling 47
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
35 40
AH-A07BE / AH-A07BE-C / AH-A09BE / AH-A09BE-C / AH-A12BE
Temperature at each part and pressure in 3-way valve
Model
1
2
3
4
3-way valve
pressure (MPaG)
76˚C
44˚C
11˚C
8˚C
0.53
76˚C
40˚C
13˚C
7˚C
0.49
81˚C
42˚C
12˚C
10˚C
0.5
Dimension of Capillary tube
AH-A07BE/A07BE-C
AH-A09BE/A09BE-C
AH-A07BE/A07BE-C
AH-A09BE/A09BE-C
AH-A12BE
Model
ø2.7
ø2.7
ø2.7
O.D
ø1.4 ø1.5
ø1.6
400
600
I.D L
O.D
I.D L
O.D
I.D L
500
Capillary tube
AH-A09BE/A09BE-CAH-A07BE/A07BE-C AH-A12BE
Indoor side
Standard conditions:
Dry-bulb Temp. (˚C) Relative Humidity (%)
20Heating
Outdoor side
Dry-bulb Temp. (˚C) Relative Humidity (%)
787
27Cooling 47 35 40
AY-A07BE / AY-A07BE-C / AY-A09BE / AY-A09BE-C / AY-A12BE
Temperature at each part and pressure in 3-way valve
NO.
Condition
Cooling Heating Cooling Heating Cooling Heating
Model
1
2
3
4
3-way valve
pressure (MPaG)
0.54 1.51 0.52 1.54 0.52 1.62
41˚C
70˚C
12˚C
7˚C
74˚C
3˚C
32˚C
3˚C
75˚C
43˚C
13˚C
8˚C
74˚C
2˚C
32˚C
3˚C
41˚C
78˚C
14˚C
11˚C
73˚C
3˚C
32˚C
4˚C
Dimension of Capillary tube
AY-A12BE
Model
ø2.7
ø2.7
O.D
ø1.6
ø1.6
150
I.D L
O.D
I.D L
O.D
I.D L
150
Capillary tube C
ø2.7
ø2.7
ø2.7
ø1.4 ø1.5
ø1.6
700
700
700
Capillary tube B
ø2.7
ø2.7
ø2.7
ø1.4 ø1.5
ø1.6
600
500
400
Capillary tube A
AY-A09BEAY-A07BE AY-A12BE
REFRIGERANT PIPE LENGTH 7.5m
REFRIGERANT PIPE LENGTH 7.5m
Model
O.D
I.D L
O.D
I.D L
Capillary tube C
ø2.7
ø2.7
ø1.4 ø1.5700
700
ø2.7
ø1.6
150
Capillary tube B
ø2.7
ø2.7
ø1.4 ø1.5500
400
Capillary tube A
AY-A09BE-CAY-A07BE-C