AR-M550/M620/M700 SIMULATION 8 - 11
24 1 Used to clear the misfeed counter,
the misfeed history, the trouble
counter, and the trouble history. (The
counters are cleared after
completion of maintenance.)
Data clear Counter
2 Used to clear the number of use (the
number of prints) of each paper feed
section.
Data clear Paper feed Counter
3 Used to clear the number of use of
the finisher, SPF, and the scan
(reading) unit.
Data clear Counter
4 Used to reset the maintenance
counter.
Data clear Counter
5 Used to reset the developer counter.
(The developer counter of the DV
unit which is installed is reset.)
Data clear Counter Developer
6 Used to reset the copy counter. Data clear Counter Copy
7 Used to clear the OPC drum counter.
(Perform this simulation when the
OPC drum is replaced.)
Data clear Image process
(Photoconductor/
Developing/
Transfer/Cleaning)
Counter Photo
conductor
9 Used clear the printer mode print
counter and the self print mode print
counter.
Data clear Printer Counter
10 Used to clear the FAX counter. (Only
when FAX is installed)
Data clear FAX Counter
11 Used to reset the OPC drum rotation
time, and the DV unit rotation time
counter. The developer counter in
the DV unit installed is reset.
Data clear Image process
(Photoconductor/
Developing/
Transfer/Cleaning)
Counter Developer
15 Used to clear the counters related to
the scan mode and the internet FAX
mode.
Data clear Counter
25 1 Used to check the operations of the
developing section (toner
concentration, humidity and toner
concentration sensor, humidity
sensor). (The toner concentration
sensor output can be monitored.)
Operation test/Check Process
(Developing
section)
Operation
2 Used to make the initial setting of
toner concentration when replacing
developer.
Setting Image process
(Photoconductor/
Developing/
Transfer/Cleaning)
26 2 Used to set the paper size of the
large capacity tray (LCC) and the
paper feed tray 2. (When the paper
size is changed, this simulation must
be executed to change the paper
size in software.)
Setting Paper feed Setting
3 Used to set the specifications of the
auditor. Setting must be made
according to the auditor use
conditions.
Setting Auditor Specifications
5 Used to set the count mode of the
total counter and the maintenance
counter.
Setting Specifications Counter
6 Used to set the specifications
(paper, fixed magnification ratio,
etc.) of the destination.
Setting Specifications Destination
10 Used to set the network scanner trial
mode.
Setting Operation
Code
Function (Purpose) Purpose Section Item