CVP09LX
2 – 5
22.Cut the fixing band holding the wires.(7 parts)
Disconnect 8 connectors.
CAUTION: CONNECT THE CONNECTORS OF FAN MOTOR ETC.
CORRECTLY WHEN RE-ASSEMBLYING.
CN6 : OUTDOOR FAN MOTOR(BLACK AND SMALL)
CN4 : INDOOR FAN MOTOR(WHITE AND SMALL)
CN3 : INDOOR FAN MOTOR(WHITE AND LARGE)
CN5 : OUTDOOR FAN MOTOR(BLACK AND LARGE)
CN13 : LEAD WIRE FOR FLOAT SWITCH ASS'Y(4P)
23.Cut the fixing band holding the wires.(1 part)
24.Cut the fixing band holding the wire and tape.
Then remove the tape.
CAUTION: KEEP THE TAPE IN CASE OF RE-ASSEMBLYING.
Then cut the fixing band holding the wires.
25.Disconnect the micro switch connector.
*Lower micro switch only.
26.Unscrew 3 screws holding the wire holders.
27.Remove wiring connectors of the compressor cord by using long-
nose pliers.(3 parts)
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUN-
NING CAPACITOR BEFORE TOUCHING THESE CAPAC-
ITORS OR OTHER COMPONENTS OR WIRING.