INSTANT LOW WATTAGE
OPERATION
The air conditioner will operate with reduced
maximum power and excess power con-
sumption will be avoided.
1
During operation, press the
INSTANT LOW WATTAGE
button to select desired maxi-
mum wattage.
• The POWER CONSUMPTION indicator
will change each time you press the but-
ton.
(AH-XP18MV)
Maximum
wattage
POWER CONSUMPTION
indicator
Free
power consumption
1.0 kW
(Blinking)
power consumption
(When below 1.0 kW)
0.8 kW
(Blinking)
power consumption
(When below 0.8 kW)
(AH-XP24MV)
Maximum
wattage
POWER CONSUMPTION
indicator
Free
power consumption
1.5 kW
(Blinking)
power consumption
(When below 1.5 kW)
1.0 kW
(Blinking)
power consumption
(When below 1.0 kW)
NOTE:
• The unit memorizes the previous INSTANT
LOW WATTAGE setting and will be activated
the next time operated.
• INSTANT LOW WATTAGE operation can not
be available when the unit is in PLASMA-
CLUSTER operation at FAN mode and SELF
CLEAN operation.
• When power consumption is controlled by the
INSTANT LOW WATTAGE function, “L1” or
“L2” is displayed on the POWER CONSUMP-
TION indicator.
1
POWER CONSUMPTION
INDICATOR
Indicates power consumption.
NOTE:
• After “H” is indicated in the rst second, power
consumption is indicated. (When INSTANT
LOW WATTAGE is set, “L1” or “L2” is dis-
played rst.)
• During PLASMACLUSTER operation at FAN
mode and SELF CLEAN operation, power
consumption will not be displayed.
• “0.1” is displayed on the indicator when the
power consumption is less than 0.1 kW.