FDD412A/B
(5)
Door
lock
control
mode
Set
the
required
door
lock
control
mode
by
installing
a
shorting-
plug
according
to
the
following
table:
Table
3.5
Setting
of
Door
Lock
Control
Mode
DOOR LOCK
SET/RESET-N
Signal
/
JP2
Shorted
across
1
to
2
Shorted
across
1
to
3
When
the
HEAD
ENGAGE-N
signal
is
input,
the
door
is
locked
independent
of
the
above
setting.
(6)
Terminator
The
terminator
consists
of:
a
DIP
type
resistor
module
and
jumper
connector
JP1
(7%8).
Perform
setting
as
follows:
Table
3.6
Terminator
Setting
DIP
Type
Resistor
Module
Installed
in
IC
socket
Not
installed
in
IC
socket
The
following
type
of
shorting-plug
is
recommended:
Terminator
Provided
Shorted
across
7
to
8
Not
provided
Open
across
7
to
8
8261
series
ELBIT
type
II
(available
from
guco)
No.
00-8261-0242-00-870