EasyManua.ls Logo

Sharp LC-80LE857U - Page 79

Sharp LC-80LE857U
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LC-60/70/80LE650U/LE657U/C6500U/LE757U/LE857U,60/70LE755U/C7500U
5 – 16
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
LEV30116 Level Reference value Adjustment spec Inspection spec
MG3G****
Point 6 916
X=0.272
±0.0010 ±0.0020
MG3B**** y=0.277
MG3R****
Point 5 692
X=0.272
±0.0010 ±0.0020
y=0.277
Point 2
Point 4 532
X=0.272
±0.0015 ±0.0030
LEV20074 y=0.277
MG2G****
Point 3 464
X=0.272
±0.0020 ±0.0040
MG2B**** y=0.277
MG2R****
Point 2 296
X=0.272
±0.0030 ±0.0060
y=0.277
Point 1
Point 1 180
X=0.272
±0.004 ±0.0080
LEV10045 y=0.277
MG1G****
MG1B****
MG1R****
Writing
MSET0003
Remarks Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-80LE757U:Min 280cd/m2
LC-80LE857U:Min 369.6cd/m2
Adjustment
point
Adjustment conditions Adjustment procedure

Table of Contents