PROCESS SECTION – COLOUR:
(When Colour maintenance counter has reached the specified life).
Replace Cyan, Magenta & Yellow OPC Drum: (MX-60GRSA x 3)
Replace Cyan, Magenta & Yellow Main Charge Kits:-
Main Charge Unit & Cleaning Blade (MX-407MK x 3)
Replace C, M, Y Developer (MX-60GVSA).
Clean LSU Dust Proof Glass (CMYK)
Sim 24-04 Clear Drum CTRG C, M, Y (Colour) Counters.
Clear Main Charger C, M, Y (Colour) Counters.
Clear Drum Blade C, M, Y (Colour) Counters.
Clear Maintenance [Colour] Counter.
Sim 24-05 Clear Developer C, M, Y (Colour) Counters.
Sim 25-02 Toner Concentration Auto Adjustment - Select C, M, Y.
If ALL developer is replaced at the same time, select CMYK.
When Sim 25-02 is executed, the Developer Counter
(Sim 24-05) is also cleared automatically.
Ensure ALL toner cartridges are removed, prior to executing
Sim 25-02.
Sim 44-27 Clear Half Tone Process Correction.
PROCESS SECTION -MONOCHROME:
(When Total / K maintenance counter has reached the specified life).
Replace Black OPC Drum (MX-60GRSA).
Replace Black Main Charge Kit:-
Main Charge Unit & Cleaning Blade (MX-407MK).
Replace Black Developer (MX-60GVBA).
Clean LSU Dust Proof Glass (CMYK)
Sim 24-04 Clear Drum CTRG K (Black) Counter.
Clear Main Charger K (Black) Counter.
Note: MC Cleaner Counter [K] is also cleared automatically.
Clear Drum Blade K (Black) Counter.
Clear Maintenance [ALL] Counter.
Sim 24-05 Clear Developer K (Black) Counter.
Sim 25-02 Toner Concentration Auto Adjustment - Select K.
If ALL developer is replaced at the same time, select CMYK.
When Sim 25-02 is executed, the Developer Counter
(Sim 24-05) is also cleared automatically.
Ensure ALL toner cartridges are removed, prior to executing
Sim 25-02.