TEST
PROCEDURES
(CONT'D)
a
A
A
PROCEDURE
LETTER
COMPONENT
TEST
K
BLOWN
FUSE
F1
F6.3A
CARRY
OUT
3D
CHECKS;.ssp
If
the
ovens
internal
fuse
F1
F6.3A
is
biown
when
the
door
ts
opened,
check
the
1st
latch
switch,
monitor
switch
and
monitor
resistor.
If
the
fuse
F1
F6.3A
is
blown
by
incorrect
door
switching
replace
the
defective
switch(s)
and
the
fuse
F1.
F6.3A.;.ssp
CARRY
OUT
4R
CHECKS
CAUTION:
Only
replace
fuse
with
the
correct
value
replacement.
L
BLOWN
WEAK
POINT
WP
A017
CARRY
OUT
3D
CHECKS;.ssp
If
the
weak
point
WP
A017
is
biown,
there
is
a
shorts
or
grounds
in
electrical
parts
or
wire
harness.
Check
them
and
replace
the
defective
parts
or
repair
the
wire
harness.
CARRY
OUT
4R
CHECKS
CAUTION:
Only
replace
weak
point
with
the
correct
value
replacement.
a
M
BLOWN
FUSE
F2
F8A
CARRY
OUT
3D
CHECKS:.ssp
If
the
fuse
F2
F8A
is
blown,
there
is
a
short
in
the
asymmetric
rectier
or
there
is
a
ground
in
wire
harness.
A
short
in
the
asymmetric
rectifier
may
be
occured
due
to
short
or
or
ground
in
H.V.
rectifier,
magnetron,
power
transformer
or
H.V.
wire.
Check
them
and
replace
the
defective
parts
or
repair
the
wire
harness.
CARRY
OUT
4R
CHECKS
CAUTION:
Only
replace
weak
point
with
the
correct
value
replacement.
N
CONVECTION
HEATING
ELEMENT
AND
GRILL
HEATING
ELEMENT
TEST
CARRY
OUT
3D
CHECKS;.ssp
Before
carring
out
the
following
tests
make
sure
the
heating
ele-
ment
is
fully
cool.
1.
Resistance
of
heating
element
Disconnect
the
wire
leads
to
the
heating
element
to
be
tested.
Using
ohmmeter
with
low
resistance
range.
Check
the
resistance
across
the
terminals
of
the
heating
element
as
de-
scribed
in
the
folowing
table.
Table:
Resistance
of
heater
Convection
heating
element
ā€œGrill
heating
elements
Resistance
Approximately
359
0
Approximately
51
Q
(Resistance
of
each
element
is
approx.
25.5
Q)
2.
Insulation
resistance
Disconnect
the
wire
leads
to
the
heating
element
to
be
tested.
Check
the
insulation
resistance
between
the
element
and
cavity
using
a
500V
-
100MQ
insulation
tester.
The
insulation
resisttance
should
be
more
than
10MQOQ
in
the
cold
start.
If
the
results
of
above
test
1
and/or
2
are
out
of
above
specifications,
the
heating
element
iS
probably
faulty
and
should
be
replaced,
CARRY
OUT
4R
CHECKS
i
19