EasyManua.ls Logo

Sharp TMV Series - Page 11

Sharp TMV Series
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
3. Quill feed:
a. Manual feed:
Turn the feed rate selector to any of the two "DUMMY" positions.
Engage feed trip lever from (B) to (B')
The quill is now under hand wheel (G) control
b. Automatic feed:
Ensure quill lock is off (C)
Set micrometer dial to required depth, (D)
Engage Feed Clutch Selector (E)
Select feed rate, (A)
Engage feed trip lever (B) to (B')
The feed will automatically trip out at a depth within 0.2 mm.
Note: 1. To interrupt power feed, just press down the disengagement lever (F).

Related product manuals