EasyManua.ls Logo

Sherwood 420 User Manual

Sherwood 420
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
425 91 001 Issue 22 2
nd
December 2016 ECN 1410 & 1932
W:\DOCUMENT CONTROL\Manuals\Flame\425\42591001 M420 & M425 Operator Manual Issue 22.doc
Model 420 and Model 425
Flame Photometer
Operator Manual
Sherwood Scientific Limited
1 The Paddocks
Cherry Hinton Road
Cambridge
CB1 8DH
United Kingdom
Copyright © Sherwood Scientific Limited 2017

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sherwood 420 and is the answer not in the manual?

Sherwood 420 Specifications

General IconGeneral
BrandSherwood
Model420
CategoryMeasuring Instruments
LanguageEnglish

Summary

Short Form Instructions

Set Up and Ignition

Steps for initial setup, gas connection, and instrument power-on.

Blanking (Zeroing)

Procedure to zero the instrument using a blank solution.

Calibration Process

Process for calibrating the instrument with standard solutions.

Measuring a Sample

Steps for aspirating and measuring a sample.

Introduction

Contacting Sherwood Scientific

Contact details and resources for Sherwood Scientific.

Using this Manual

Guidance on how to navigate and use the manual effectively.

Safety Precautions

Essential safety warnings and guidelines for instrument operation.

Reagents Information

Information on required reagents and solutions for operation.

Dilution Methods

Explains dilution methods and modes for sample preparation.

BlueNotes Software

Details on the BlueNotes software for extended instrument capabilities.

Warranty Information

Information on the product warranty terms and coverage.

Installation Procedures

Location Requirements

Specifies ideal environmental and physical placement for the instrument.

Services Required

Outlines necessary electrical, fuel, and air supply requirements.

Unpacking and Accessories

Guide to unpacking the instrument and verifying accessory contents.

Assembly Procedures

Step-by-step instructions for assembling the instrument.

Connecting Peripheral Devices

How to connect printers, computers, and autosamplers.

Setting Date and Time

Procedure for configuring the instrument's date and time settings.

Setting Filter Factors

Instructions for setting internal filter factor values.

Units Configuration

How to select and configure measurement units.

Principles of Operation

Application of Flame Photometry

Overview of flame photometry applications and historical context.

Principles of Flame Photometry

Explains the scientific principles behind flame photometry.

The Internal Standard Mode

Details the use of the internal standard for improved accuracy.

Performance Characteristics & Specifications

Readout Display

Describes the instrument's display type and range.

Measurement Ranges

Specifies the concentration ranges for analysed elements.

Specificity and Interference

Information on element interference and measurement specificity.

Accuracy and Performance

Covers linearity, drift, and reproducibility of measurements.

Warm Up Time

Recommended warm-up period for achieving optimal performance.

Sample Requirements

Guidelines on sample types, dilution ratios, and volume.

Chart Recorder Output

Details on adjusting the analogue output for chart recorders.

Environmental Conditions

Specifies operating temperature and humidity limits.

Power Requirements

Information on voltage, power consumption, and frequency.

Fuel Specifications

Requirements for fuel type, pressure, and quality.

Air Supply Specifications

Details on air pressure, flow rate, and compressor type.

Instrument Dimensions

Physical size specifications of the instrument.

Instrument Weight

The total weight of the instrument.

Description of Instrument

Front Panel Controls and Indicators

Overview of all controls and status indicators on the front panel.

Rear Panel Connections and Ports

Identification and description of all rear panel connectors and ports.

Operating Modes

Explanation of different measurement modes and operational sequences.

Operating the Instrument

Start Up Procedure

Comprehensive steps for powering on and preparing the instrument.

Blanking and Calibration

Procedures for blanking and calibrating the instrument.

Sample Measuring

Detailed steps for measuring samples in different modes.

Automatic Operation

Using the instrument with autosamplers and diluters.

Sample Numbering

System for tracking and numbering samples during operation.

Shutdown Procedure

Steps for safely powering down the instrument.

Operating Hints, Precautions & Limitations

General Hints

Practical tips for optimizing instrument performance and accuracy.

Operational Precautions

Important precautions to follow during instrument operation.

Hazards and Safety

Identifies potential hazards and necessary safety measures.

Measuring Calcium

Specific considerations for measuring calcium with the Model 425.

Cleaning and Maintenance Procedures

General Maintenance Overview

Introduction to the maintenance schedule and requirements.

Daily Maintenance

Routine daily tasks for instrument upkeep.

Weekly Maintenance

Tasks to be performed on a weekly basis.

Monthly Maintenance

Tasks for monthly instrument maintenance.

Six Monthly Maintenance

Maintenance procedures to be carried out every six months.

Nebuliser Maintenance

Procedures for checking and cleaning the nebuliser.

Cleaning Chamber, Burner, and Drain

Instructions for cleaning key internal components.

Cleaning Filters and Glass Chimney

Procedures for cleaning optical filters and the glass chimney.

Deproteinising or Disinfecting Procedure

Steps for cleaning and disinfecting the system.

Accessories, Consumables & Spare Parts

Ordering Information

Guidance on how to order replacement parts and accessories.

Spares and Accessories List

A list of available spare parts and accessories with catalogue numbers.

Reagents List

A list of chemical reagents and solutions for use with the instrument.

Appendix A

Bibliography

A list of referenced scientific literature.

Appendix B

Error Messages and Troubleshooting

A guide to error codes and their solutions.

Appendix C

Using Zero offset and Span Control

Advanced feature for calibrating the instrument via analogue output.

Product Warranty Statement

Warranty Terms and Conditions

Details the warranty period, coverage, and exclusions.

Related product manuals