Input Voltage | 220V AC |
---|---|
Output Current | 10A |
Power | 240W |
Operating Temperature | -10°C to 50°C |
Protection | Overload, Short Circuit, Over Temperature |
Weight | 1.5kg |
Ensures safe cable laying, controller placement in safe rooms, and adherence to environmental conditions.
Details the manual's scope, covering installation, function, and operation of the solar thermal controller.
States the manufacturer's disclaimer for damages due to improper installation, operation, or utilization.
Explains safety instructions (warning triangles) and operation steps (small triangles).
Instructions for safely opening and closing the controller case, including screw removal and reassembly.
Guidance on selecting a suitable location and physically mounting the controller.
Covers preparation for electrical connections, ensuring IP protection class is maintained.
Procedure to set the current time and day of the week on the controller.
Procedure to select the appropriate solar system configuration from available options.
Manual control of controller outputs for testing functions, such as circulation pumps.
Method to check temperature values from sensors T0-T5 on the controller display.
Setting and displaying the current time and week on the controller's LCD screen.
Procedure to select one of the 8 available system configurations for the controller.
Details configuration for System 1: 1 collector, 1 storage tank, 1 pump, and related sensor/output connections.
Configuration for System 2: 1 collector, 2 storage tanks, 2 pumps, detailing connections and operation.
Configuration for System 3: 1 collector, 2 storage tanks, 1 pump, 1 valve, specifying connections and logic.
Configuration for System 4: 2 collector arrays, 1 storage tank, 2 pumps, outlining operational logic.
Configuration for System 5: 2 collector arrays, 1 storage tank, 1 pump, 1 valve, detailing connections.
Configuration for System 6: 2 collector arrays, 2 storage tanks, 1 pump, 2 valves, detailing operational logic.
Configuration for System 7: 2 collector arrays, 2 storage tanks, 2 pumps, 1 valve, detailing operational logic.
Configuration for System 8: 2 collector arrays, 2 storage tanks, 2 pumps, 1 valve, detailing operational logic.
Sets switch-on and switch-off temperature differences to control solar circuit pump operation.
Protects the tank by stopping the solar circuit pump if the temperature exceeds a set limit.
Prevents overheating by controlling collector temperature, potentially activating the solar pump for cooling.
Shuts off the solar circuit pump if collector temperature exceeds 130°C for component protection.
Prevents solar pump operation below 15°C, even if temperature difference is met.
Activates booster and solar pump below frost protection temperature to prevent freezing.
Controls the hot water circulation pump (P2) based on return pipe temperature (T4).
Enables time-scheduled operation of the hot water circulation pump (P2).
Controls auxiliary heating based on tank temperature (T3) and time sections.
Activates nightly tank cooling to prevent high thermal loads when the system is not in use.
Enables additional functions like temperature difference control (ΔT2) using output port R2.
Resets all system parameters to factory default settings.
Includes memory protection, anti-bacteria, and anti-dry heating protection features.
Describes error indications for sensor breaks or short circuits and their rectification.
Guides on checking for common system problems and identifying potential causes and procedures.
Provides a table of functions, factory settings, and remarks for system parameter configuration.