Display Meaning / possible causes Troubleshooting
Pre-failure recognition The measurement laser is still operational
but at the end of its service life.
Keep replacement device ready.
Current damping value is below the recom-
mended damping value. The recommended
damping value depends on the distance
betweenmeasuringdeviceandreector.
For recommended damping values, see
page 29, table 5.
Clean external lens surfaces like the
reectorandthelens
Lensorreectorcontaminated. Clean external lens surfaces like the
reectorandthelens
The internal devicetemperature is within the
threshold range. For the permissible am-
bient temperature, see page 106, chapter
14.8.
Check ambient temperature.
Table 61: PROFINET IO error messages
12.5 Return
Forecientprocessingandquickdeterminationofcauses,includethe
following in your return:
Information on a contact
A description of the application
A description of the error that occurred
12.6 Disposal
Observe the following items for disposal:
The distance measuring device must not be disposed of in the house-
hold waste.
Dispose of the distance measuring device according to the respective
country-specicprovisions.
13 Repair
Repairs must only be performed by the manufacturer. The manufacturer's
warranty will lapse in case of interruptions and changes to the device.