8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 107
Technical data
14.5 Inputs
Inputs Multifunction input MF1, adjustable
Hi > 12 V
Lo < 3 V
See page 46, Table 15, parameter “ActSta”.
Protective circuit No, not reverse polarity protected
Table 65: Inputs
14.6 Outputs
Outputs Multifunction outputs MF1 and MF2, type: B (push/pull), adjustable
Hi > UV – 3 V
Lo < 2 V
See page 46, Table 15 and page 52, Table 20, parameter “ActSta2.
Maximum output current Max. 100 mA
Output load Capacity: 100 nF
Inductive 20 mH
Table 66: Outputs
14.7 Interfaces
Data interface PROFINETIO/RT,ConformanceClassB,PNspecicationV2.3,
Process data interface, access via SOPAS ET
Data transmission rate 100 Mbit/s fullduplex
Table 67: Interfaces