108 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
14.8 Ambient conditions
Protection class III
Suitable for operation in PELV systems (Protective Extra Low Voltage -
safety extra-low voltage) with secure separation.
Electromagnetic compatibility
1)
EN 61000-6-2, EN 55011, category A
Ambient temperature range Devicewithoutheating:–20…+55°C
2)
Devicewithheating:–40…+55°C
3)
Storage temperature range –40°C…+75°C
Enclosure rating IP65
Airpressureinuence 0.3 ppm/hPa
Temperatureinuence 1 ppm/K
Temperature drift Typical 0.1 mm/K
Maximum movement speed 15 m/s
Maximum acceleration change 15 m/s²
Vibration resistance (sine) EN60068-2-6
Noise EN60068-2-64
Shock resistance EN 60086-2-27
1) When used in the household area, the device may cause interferences.
2) A warm-up time of typically 7 minutes is required at temperatures below
–10 °C.
3) For the heated variant, a warm-up time of typically 16 minutes (at 24 V) is required at –40 °C.
Table 68: Ambient conditions
14.9 Constructive setup
Dimensions
→ See page 105, chapter 14.1.
Weight • Distance measuring device: 800 g
• Alignment bracket (optional): 800 g
Materials • Casing: Cast aluminium GD-AlSi12Cu1 (3.2982.05)
• Front screen: PMMA
Connections M12, SpeedCon™
Display • 6 points with a 5 x 7 point matrix
• Overowisdisplayedwiththemaximumvaluethatcanbedisplayed,
–99999 bzw. 999999.
Table 69: Constructive setup