Mounting
6.3 Chooseandmountreector
NOTE!
For suitable reectors and suitable reective tape, see
page 109, chapter 15.1
Reectorsize Selectthereectorsizesothatthelightspotdoesstillmeetthereector
in case of vibrations.
Ifthereectorisinstalledatavehicle,asmallerreectoristypically
sucient.
Requirements Highlyreectivesurfacesclosetothereectorcancausebeamdeec-
tions or stray light and thus lead to incorrect measurements. Highly re-
ectivesurfacesmaybe,amongothers,shelfproles,paletteswrapped
with stretch foil and running rails.
When mounting the distance measuring device in the horizontal axis of
stackercrane,inclinethereectortowardstheceiling,awayfromtherail
(approx. 1°to 3°). Seefollowinggure.
When mounting in the vertical axis, incline away from the stacker
crane‘s mast (approx. 1°to 3°). Seefollowinggure.
S
et
E
s
c
<
<
ca. 1° … 3°
S
e
t
E
sc
<
<
ca. 1° … 3°
Fig. 8: Installing the reector on highly reective surfaces
Left: Installed in driving axis, installed at the right in the lifting axis
1 Distance measuring device
2 Highly reective surface
3 Reector
4 Inclination of approx. 1° to 3°