8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 55
Operation at the measuring device
Menu “SpecFu”
(continued)
Parameter Description
FMode Requirements for the display
• Only for versions with frequency switching DL100-xxxBxxxx
Select frequency range Frequency switching may be required
at parallel placement of several distance measuring devices.
→ also see page 28, chapter 6.4.
Options
• Mode 1
• Mode 2
• Mode 3
Factory setting
• Mode 1
Reset
Perform reset → see page 55, chapter 8.6.
Table 22: Menu “SpecFu”
8.6 Perform reset
1. Select the parameter "Reset" in the menu "SpecFu".
→ See page 53, chapter
2. Push the key
.
3. The safety request "Sure?" is displayed.
4. Push the button
to reset the measuring device to the delivery state.
Push the key to cancel the process.