8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 59
Operation via Ethernet (Ethernet interface)
Field "Measurement values"
Parameter Description
Distance Measurementvalue"Distance"afterlter,correctionsand
oset
Read/Write access
• Read only
Unit
• m
Velocity Measurement value "Speed"
Read/Write access
• Read only
Unit
• m/s
Acceleration Measurement value "Acceleration"
Read/Write access
• Read only
Unit
• m/s
2
Table 31: Page "Measured data" – eld "Measurement values"
9.2.4 Diagnostic data
Field Description
Device state Display device status: ready for operation, warning(s) active,
error active, laser activated, MF1 active and MF2 active
Read/Write access
• Read only
Device warning Display of current warnings: Laser, temperature, level and
plausibility
Read/Write access
• Read only
Device error Display of current errors: Laser, temperature, level and plausi-
bility
Read/Write access
• Read only
Level Display of the current reception level (damping value)
Read/Write access
• Read only