EasyManua.ls Logo

SICK DL100 Pro - PROFINET IO High Feature - PROFINET IO-Interface; Device Configuration

SICK DL100 Pro - PROFINET IO High Feature
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 69
PROFINET IO-interface
10 PROFINET IO-interface
The distance measuring device DL100 Pro PROFINET IO supports Ethernet
networks with a transmission rate of 100 Mbit/s and PROFINET RT, Con-
formanceClassBaccordingtospecicationPROFINETV2.3.
Furthermore, the functions of auto negotiation, auto cross over and full
duplex are implemented. The DL100 Pro has an integrated dual port switch
and can be used in star or line topology. The following functions are sup-
ported by the device amongst others: Media Redundancy (MRP), Topology
Detection (LLDP), Device Replacement with out exchangeable medium/PG
function and MIB/SNMP.
I&M functions
(Identication&Maintenance
Function)
The following I&M functions are supported:
I&M0:Deviceidenticationn
I&M1: User may enter plant and location mark (AKZ and OKZ)
I&M2: Installationsdatum
I&M3: Installation date
I&M4:Signature(cong-CRC)
I&M5:Interfaceidentication
The software version in the I&M function IM0 describes the version of the
PROFINET interface and is not identical with the version number of the sen-
sorrmware.
10.1 Deviceconguration
The distance measuring devices DL100 Pro have a PROFINET IO-interface.
Thedevicesareconguredbydevicedescriptionle(GSD).
NOTE!
The GSD le for the distance measuring device
DL100 Pro can be downloaded from
“www.sick.com/dl100”.
TheGSDledenesmoduleswithwhichthedierentcontroltaskscanbe
adjustedexibly.
Also see page 71, chapter 10.2 10.2 “Modules for cyclic data transmis-
sion“ and page 76, chapter 10.3 “Module description“.

Table of Contents