8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 93
PROFINET IO-interface
10.3.11 Module 22: "Setup Preset Static"
Type Congurationmodule,noinputandoutputdata
Description This module is used to pre-set the static preset value.
Notes When module 5 is also active, the preset value is overwritten at once by
the input data of module 5.
Module parameter
Name Description
Distance Preset
Static [mm]
Determine distance Preset value.
Value range
–300000...+300000
Standard value
0
10.3.12 Module23:"SetupOset"
Type Congurationmodule,noinputandoutputdata
Description Thismoduleisusedtosettheinitialoset.
Notes Whenmodule5isalsoactive,theosetvalueisoverwrittenbythe
calculatedosetwhentheresetfunctionistriggered.Thesameappliesfor
a switching process by MF1.
Module parameter
Name Description
DistanceOset
[mm]
Determineinitialdistanceosetvalue.
Value range
–600000...+300000
Standard value
0
10.3.13 Module 25: "Special Functions"
Type Congurationmodule,noinputandoutputdata
Description Thismodulecanbeusedtoinuencetheconductofthemeasuring
algorithm, temperature stability by setting of the temperature threshold for
activation of the heating and the frequency mode.