Operating Instructions Chapter 2
ICR880/890
Safety information
8011325/XL85/2013-08-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 15
ous reading pulse. This, however, does not switch off the reading pulse. The reading
pulse should be stopped via a relevant pulse signal. The next reading pulse switches
the illumination back on.
The illumination timeout can be set or switched off within a range of 3 s to 25 h. For
safety reasons, the minimum illumination power on time is 3 seconds.
2.4 Quick stop and quick start
The Camera System is operated via the MSC800 Controller as standard and can be
switched on and off using the controller main switch.
2.4.1 Switch off the Camera System
Switch off the power supply of the MSC800.
When the Camera System is switched off the following data is lost:
Application-specific parameter sets in the Camera System and in the MSC800 Control-
ler which were only temporarily saved in the devices
The last reading result of the Camera System
Daily operating hours counter of the Camera System
2.4.2 Switch on the Camera System
Switch on the power supply of the MSC800 again.
The Camera System starts up using the most recent permanently saved configuration.
The daily operating hours counter is reset.
2.5 Environmental information
The Camera System has been constructed with minimum environmental pollution in mind.
Excluding the housing, the Camera System does not contain any materials using silicone.
2.5.1 Energy requirements
The Camera System is electrically powered via the MSC800 Controller as standard (func-
tional extra-low voltage in accordance with IEC 60364-4-41). The Camera System and the
logic controller of the MSC800 controller have the following power consumption at 24 V DC
± 20 % and ambient temperature 20 °C (68 °F):
Device type Power consumption
ICR880/890 Camera typical 75 W (via power supply unit of MSC800)
ICI890 illumination
(via power supply unit of MSC800)
Red Illumination (amber):
ICI890-00000 (1,100 mm(43.34in): typical 160 W
ICI890-01000 (900 mm(35.46 in)): typical 130 W
ICI890-01100 (900 mm(35.46 in)): typical 130 W
ICI890-02100 (750 mm (29.55 in)): typical 80 W
Blue/white Illumination:
ICI890-10000 (1,100 mm(43.34in): typical 260 W
ICI890-11000 (900 mm(35.46 in)): typical 210 W
ICI890-11100 (900 mm(35.46 in)): typical 210 W
ICI890-12100 (750 mm (29.55 in)): typical 130 W
MSC800-0000 (logic controller) typical 10 W
Tab. 2-2: Power consumption of the Camera System